Technical Specifications |
Input : |
Thermocouple / RTD sensor |
Resolution : |
10C Standard 0.10C
optional |
Sensor break protection : |
Built-in, relay OFF and display reads
1 |
Accuracy
Set point : |
Absolute |
Control Mode : |
ON/OFF with standard 10C
hysteresis Or Time proportioning with standard + 100C Bandwidth and 20 seconds cycle time
centred around
set point. |
Control Output : |
Standard 5Amp, 230V AC SPDT mechanical
relay. |
Cold junction compensation : |
Automatic |
Indication &
Control drift : |
<0.30C, constant after
18 hours (Test condition-Ambient @ 450C,
Cr/AI thermocouple for worst case) |
Control response time : |
20 milli seconds standard |
Indication response
time : |
200 milli seconds typical |
Common mode rejection : |
90dB@50Hz |
Input filter cutoff : |
10KHz |
Display : |
Easy-to-read 12.5mm high 7 segement
LED display Or 1 inch high 7-segment LED display in
96H x 96W mm instrument |
Operating temperature : |
50C to 550C |
Input power : |
230V Ac, + 20% @ 50Hz |
Dimensions : |
96H x 96W x 110D mm
74H x 74W x 110D mm |
| |
|
|
 |