| Products :- |
|
Useful For Steel ( Mild Steel, Stainless Steel, Cast Steel,
Cast Iron And Alloys ) Aluminum, Copper, Lead, Tin, Brass, Alloys,
Plastics ( PVC, PP, LDPE, HDPE ) & Glass Ceramic |
|
|
Ultrasonic Thickness Gauge
Portable Model DT1-C & DT1 |
Ultrasonic Thickness Gauge Pocket Model DT2-C & DT2 |
|

|

|
|
| Features :- |
| * |
Easy to
operate. |
* |
Digital
readout eliminates human error. |
| * |
Quick and
reliable. |
* |
Compact,
portable and battery operated. |
| * |
Handy and
sturdy. |
* |
Can be used
by unskilled operator. |
| * |
Accurate,
one touch, light. |
* |
Simple and
quick calibration on all materials. |
| * |
Stable
read-out to the last digit |
* |
Automatic
switch-off circuit for more battery life. |
| * |
Option of
LCD and LED display |
* |
Works
remarkably well even on rough and curved surface. |
| * |
High
penetration power. |
* |
Highly
reliable due to modern solid state technology. |
| * |
Non-destructive,
instant thickness. |
* |
Choice of
rechargeable Ni-Cd cells and dry cells. |
| * |
Measures
thickness from only one side. |
|
|
|
Advantages of
Ultrasonic Thickness Gauge
:- |
| * |
Quick thickness measurement
of parts accessible from one side only. |
| * |
Accurate measurement of
remaining wall thickness on wear parts. |
| * |
Reliable corrosion
inspection and control to guarantee the production process. |
| * |
Preventive maintenance by
early detection to avoid consequential losses. |
|
| Description :- |
Magasonic
Industries manufacture Ultrasonic Digital Thickness Gauges meant for
precise measurement of wall thickness using ultrasonic echo
principle. The instrument is supplied with a probe and Calibration Master for MS on which the instrument is to be calibrated
with a drop of oil as a couplant. After calibration the instrument is ready to check thickness of MS
articles just from one side with use of oil as couplant. The probe creates and transmits ultrasonic pulses
from the top surface of the test-piece and after traveling through the material they are reflected at
the bottom surface back to the probe. As speed of ultrasonic waves vary with material a Calibration Master for
that material ( other than MS ) is needed which is supplied as optional accessory.
The instrument
display's instantly the thickness of the test-piece with reading in
digits with accuracy + 0.1mm. It also find out thinning due to bending, forming,
drawing and detects manufacturing defects like laminations, folds, voids in plates. It helps to find out the
remaining wall thickness of pipelines etc. just from one side without counting the rust, scale formation on the
other side.
The Standard Probe
DG-210 supplied with instrument is used for plane and curved surface
like pipeline, gas cylinder etc. for higher diameter objects. Low Curvature Probe
is used for smaller diameter pipelines and Finger Tip Probe is
meant for readings in congested areas.
LCD Models ( DT2-C & DT1-C ) have bright light as well as low
ambient light visibility are meant for outdoor as well as indoor applications. LCD Models are recommended
which consumes less power as compared to LED Models ( DT2 & DT1 ) unless measurements are
always to be taken in very dark areas.
Ultrasonic Probes
:-
DG - 210 :
Standard Probe : For plane and externally curved surface like pipes,
cylinders of outer
diameter more than 50mm.
DC - 210 : Low Curvature Probe : For smaller diameter curved
surface like pipes with outer diameter
between 25 to 50mm.
DF - 206 : Finger Tip Probe : For closely spaced or congested
areas.
|
|
| Type |
DG
- 210 |
DC
- 210 |
DF
- 206 |
| Nomenclature |
Standard |
Low
Curvature |
Finger
Tip |
Thickness
Range in
Steel ( mm ) |
1.5
to 100.0 |
1.5
to 10.0 |
1.5
to 10.0 |
| Surface |
Flat
& Curved ( Above 50mm in dia. ) |
Only
curved |
Restricted |
Curvature
Range
( mm ) |
OD
50mm & above |
OD
25 to 50mm |
OD
50mm & above |
Sensing
Face
Diameter ( mm ) |
10 |
10 |
6 |
Probe
Size ( mm )
Dia X Height |
Ø
15 X 30h |
Ø
15 X 30h |
Ø
11 X 40h |
Maximum
Surface
Temp. (C) |
-
25 to + 70 |
-
25 to + 70 |
-
25 to + 70 |
| Couplant |
Ordinary
Oil,
glycerin. |
Ordinary
Oil,
glycerin. |
Ordinary
Oil,
glycerin. |
|
All probes are supplied
with cable and 5 pin connecter at one end. |
TECHNICAL
SPECIFICATIONS
( IN STEEL ) |
Pocket
Models |
Portable
Models |
| Models |
DT2-C |
DT2 |
DT1-C |
DT1 |
| Measurement
Range |
1.5mm
to 100.0mm |
| Measuring
Accuracy |
+ 0.1mm |
| Minimum
Thickness Measured |
1.5mm |
| Probes |
DG-
210 - Standard ( 2 MHz ), Optional DC - 210 - Low Curvature,
DF - 206 Finger Tip. |
| Test
Frequency |
2
MHz |
| Batteries |
7.5V
DC i.e 5 No. of Pencil Size
( AA ) cells |
9V
DC i.e 6 No. of Medium Size
(C) cells. |
| Low
Battery Indication |
Decimal
Point in display blinks |
Decimal
Point in display and front panel LED blinks. |
| Dimensions
( Approx. ) |
80mm
X 155mm X 38mm
( W X H X D ) |
195
mm X 65 mm X 140 mm
( W X H X D ) |
| Weight
( Approx. ) |
400
gm including batteries |
1.5
kg including batteries |
| Display |
LCD |
LED |
LCD |
LED |
|
|
|
|
High Precision Thickness
Gauge Useful For Mild Steel, Stainless Steel, Cast Steel,
Cast Iron, Alloys, Aluminum, Copper, Lead, Tin, Brass,
Alloys, Plastics
( PVC, PP, LDPE, HDPE ) & Glass Ceramic.
|
|
Advantages
of Ultrasonic Wall Thickness Measurement
| * |
Quick
thickness measurement of parts accessible from one side
only. |
| * |
Accurate
measurement of remaining wall thickness on wear parts. |
| * |
Reliable
corrosion inspection and control to guarantee the
production process. |
| * |
Preventive
maintenance by early detection to avoid consequential
losses. |
|
|
|
|
|
|
|
| Ultrasonic Thickness Gauge
| | High Precision Thickness Gauge
| |
|
| Home |
| Product | | Contact | | Feedback
|
Website :
www.megasonicindia.com |