CONTINUOUSLY VARIABLE (CV - CL) POWER SUPPLIES |
 |
| Features :- |
• |
Output Voltage Adjustable from 0 to Specified Voltage. |
• |
Current Limit Adjustable from 5% to 110% of Specified Load Current. |
• |
Load & Line Regulation: ± 0.05% max. |
• |
Ripple & Noise: 1 mV (r. m. S.) Max. |
• |
Protected Against Overload & Short Circuit by Means of Automatic Crossover Characteristics. |
• |
Continuous Metering of Output Voltage & Current. |
• |
Input Voltage: 230V AC ±1 0%, 50Hz, Single Phase. |
• |
Operating Temperature Range: 0 to 55°C. |
• |
Remote Sensing for Distantly Situated Loads for Models Above 5 Amps. |
|
| OPTIONAL FACILITIES : (At Extra Cost) :- |
• |
Over voltage Protection (Fixed / Variable). |
• |
Input Voltage: 115V AC ±1 0%. |
• |
Rack-Mounting, Wall Mounting, Base Mounting. |
• |
TTL Compatible Active ON / OFF. |
|
|
CONTINUOUSLY VARIABLE (CV - CL) DUAL OUTPUT POWER SUPPLIES |
 |
| Features :- |
• |
Output Voltage Adjustable from 0 to Specified Voltage. |
• |
Current Limit Adjustable from 5% to 110% of Specified Load Current. |
• |
Two Completely Isolated Outputs can be configured in Series or Parallel to Enhance
Voltage or Current Output Capacity Respectively. |
• |
Load & Line Regulation: ± 0.05% max. |
• |
Ripple & Noise: 1 mV (r. m. S.) Max. |
• |
Protected Against Overload & Short Circuit by Means of Automatic Crossover
Characteristics. |
• |
Continuous Metering of Output Voltage & Current. |
• |
Input Voltage: 230V AC ±10%, 50Hz, Single Phase |
• |
Operating Temperature Range: 0 to 55OC. |
• |
Remote Sensing for Distantly Situated Loads for Models above 5 Amps. |
|
| OPTIONAL FACILITIES : (At Extra Cost) :- |
• |
Over voltage Protection (Fixed / Variable). |
• |
Input Voltage: 115V AC ±1 0%. |
• |
Rack-Mounting, Wall Mounting, Base Mounting. |
• |
TTL Compatible Active ON / OFF. |
|
| |
'PRECISE' VARIABLE (CV - CC) DUAL OUTPUT POWER SUPPLIES |
 |
| Features :- |
• |
Output Voltage Adjustable from 0 to Specified Voltage. |
• |
Current Limit Adjustable from 5% to 110% of Specified Load Current. |
• |
Two Completely Isolated Outputs can be configured in Series or Parallel to Enhance
Voltage or Current Output Capacity Respectively. |
• |
Regulation : Voltage (CV) : Load & Lin : ± 0.01 % max.
: Current (CC) : Load & Line : ± 0.05% max. |
• |
Ripple : CV : 1 mV (r. m. s.) Max., : CC: 0.03% Amp. (r. m. s.) Max., |
• |
Protected Against Overload & Short Circuit by Means of
Automatic Crossover Characteristics. |
• |
Externally Programmable Output Voltage. |
• |
Remote Sensing for Distantly Situated Loads. |
• |
Continuous Metering of Output Voltage & Current. |
• |
Input Voltage: 230V AC ±10%, 50Hz, Single Phase. |
• |
Operating Temperature Range: 0 to 55°C. |
|
| OPTIONAL FACILITIES : (At Extra Cost) :- |
• |
Over voltage Protection (Fixed / Variable). |
• |
Input Voltage: 115V AC ±1 0%. |
• |
Rack-Mounting, Wall Mounting, Base Mounting. |
• |
TTL Compatible Active ON / OFF. |
|
| |
'PRECISE' VARIABLE (CV - CC) POWER SUPPLIES |
|
| Features :- |
• |
Output Voltage Adjustable from 0 to Specified Voltage. |
• |
Current Limit Adjustable from 5% to 110% of Specified Load Current. |
• |
Two Completely Isolated Outputs can be configured in Series or Parallel to Enhance
Voltage or Current Output Capacity Respectively. |
• |
Regulation : Voltage (CV) : Load & Lin : ± 0.01 % max.
: Current (CC) : Load & Line : ± 0.05% max. |
• |
Ripple : CV : 1 mV (r. m. s.) Max., : CC: 0.03% Amp. (r. m. s.) Max., |
• |
Protected Against Overload & Short Circuit by Means of
Automatic Crossover Characteristics. |
• |
Externally Programmable Output Voltage. |
• |
Remote Sensing for Distantly Situated Loads. |
• |
Continuous Metering of Output Voltage & Current. |
• |
Input Voltage: 230V AC ±10%, 50Hz, Single Phase. |
• |
Operating Temperature Range: 0 to 55°C. |
|
| OPTIONAL FACILITIES : (At Extra Cost) :- |
• |
Over voltage Protection (Fixed / Variable). |
• |
Input Voltage: 115V AC ±1 0%. |
• |
Rack-Mounting, Wall Mounting, Base Mounting. |
• |
TTL Compatible Active ON / OFF. |
|
| |
|
| |
| |