Distribution Transformers, Furnace Transformer, Converter Duty Transformer, Dry Transformers, Industrial Transformer, Mumbai, India
 
Distribution Transformers, Furnace Transformer, Converter Duty Transformer, Dry Transformers, Industrial Transformer

--------------------------------------------------------------------------------------------------------------------------------------------------

• Distribution Transformers

Industrial, Substation & Distribution Tfr. Upto 10 MVA, Upto 33kV, ONAN A poly phase transformer design is presented in which transformer output pores are accurately constructed in both voltage magnitude and relative phase angle. The design incorporates both main and auxiliary transformers that are used in unison to produce the accurately constructed phases. The main transformer permits rough phase adjustment to be made with the auxiliary transform permitting phase fine tuning. Such a design is particularly suitable in transformer approaches that require output phases that are of a number not evenly divisible by three.

Distribution Transformers

--------------------------------------------------------------------------------------------------------------------------------------------------

• Power Transformers

Station & Multi-winding to suit specific needs & L.T. Transformers for generating Stations. Upto 10 MVA, 3 Phase, Upto 33Kv, ONAN/ONAF/OFAF/OFWF Cooling A power transformer characterized by inner and outer low voltage winding sections and a high voltage winding section disposed there between. The low voltage windings are comprised of a plurality of pancake coils, and the high voltage winding are comprised of a plurality of conductor strands spirally wound for a plurality of coil layers. The low and high voltage winding sections are laterally spaced with the low voltage windings disposed in side-by-side positions and adjacent to the high voltage windings. The high voltage windings having a smaller turn height than the low voltage windings and having conductor strands of smaller gauge than the pancake coils of the low voltage windings.

Power Transformers

--------------------------------------------------------------------------------------------------------------------------------------------------

• Furnace Transformers
Arc, Submerged Arc, Ladle, Induction, Upto 10 MVA,Upto 33kV,ONAN/OFWF Cooling A high current furnace transformer is provided having the low-voltage windings arranged in a closed delta configuration within the transformer enclosure. Bus bar terminals are mounted exterior to the enclosure for providing electrical connection with the low-voltage windings.

Furnace Transformers

--------------------------------------------------------------------------------------------------------------------------------------------------

• Earthing Transformers 

Neutral Earthing transformers are normally provided in 3-phase system, which is without neutral and earth fault protection. Neutral earthing transformer is having zig-zag (interstar) winding to achieve the required zero phase impedance. In addition an auxiliary winding can also be provided to meet the requirement of auxiliary power supply.  ONAN /ONAF cooling with conventional pressed steel radiators. The range includes up to 33 KV systems and as per the site requirements.

Earthing Transformers

--------------------------------------------------------------------------------------------------------------------------------------------------

• Reactor Transformers

Air cored series & Shunt Reactor, Upto 2 MVA , Upto 33Kv, ONAN / AN A variable transformer, reactor having a core combining at least two complete core elements with a common yoke; primary winding divided into two independently fed sets of phase coils wound in opposite direction, arranged on symmetrical legs of core elements and separated by the common yoke; secondary winding with each phase coil divided into two wound in opposite direction portions carried by symmetrical core legs, adjacent to the primary coils and separated by common yoke. The secondary short-circuited reactor winding is reduced to at least one close loop member with loop portions separated by the common yoke. The single, poly phase apparatus has at least one primary coil per set that includes a controllable device in circuit relation therewith to enable control of one primary coil relative to the other, either in current magnitude or in current phase shift. The controllable device being either a silicon control rectifier or transistor.

Converter Duty Transformers

--------------------------------------------------------------------------------------------------------------------------------------------------

• Dry Transformers

Industrial, Substation & Distribution purpose Manufacturing range Upto 2MVA 22 KV naturally air cooled. A dry type transformer has an iron core, vacuum pressure resin impregnated high voltage windings and low voltage windings . The low voltage winding is constructed with conductors. Dupond nomex insulating material includes an apparatus to secure the windings in place during a vacuum and pressure resin impregnation process. The result is a coil that exhibits high short circuit protection due to the tightly bond conductors comparable to completely resin encased molded transformers at a substantially reduced cost.

Dry Transformers
--------------------------------------------------------------------------------------------------------------------------------------------------
[ Top ]
Websites : www.urjatransformers.com | www.distributiontransformers.net | www.furnacetransformers.net | www.compactsubstation.in |www.earthingtransformers.com | www.unitisedsubstation.com | www.drytransformers.net | www.powertransformersindia.com |
 

Designed & Hosted by : MID   Promoted by : GID